Dissimilar Metal Contact Corrosion Test [Silicoroy Technology Handbook]
Evaluation of individual test specimens! Publication of test results for "Silicoloy A2-OAG" and "SUS440" among others.
This document presents a comparison of single specimens and test specimens assembled with bolts and nuts in a dissimilar metal contact corrosion test, as well as comparisons of precipitation-hardened stainless steel and various types of stainless steel. The test specimens with bolts and nuts were combined and immersed in tap water at 65°C, and for comparison, single specimens (plate-shaped test pieces) were also evaluated. After 45 days of immersion, the test specimens were removed, and photographs of their appearance were taken. We invite you to read it. 【Contents】 ■ Test Method ■ Test Equipment ■ Test Specimen (Single) ■ Test Specimen (Bolt-Nut Combination) ■ Test Results (Single) ■ Test Results (Bolt-Nut Combination) *For more details, please refer to the PDF document or feel free to contact us.
- Company:シリコロイラボ
- Price:Other